Specifications

Copyright 2014 Carl Bright Inc. All Rights Reserved
Page 2
Internal Code 64K
External Code 64K
256 Control Registers
Bloodhound
Brain Board
Battery Backed
Up Real Time
Clock
GPRS MODEM
RSSI
8 KEY
KEYBOARD
ETHERNET
RJ45
A
NALOG
OUTPUT
HOTWIRE
REPLACEMENT
MODULE (HRM)
64K FLASH
MEMORY
REMOTELY
UPGRADEABLE
DC AMP
MONITOR
A
C VOLTS MON
A
C
FREQUENCY
PC
SERIAL
PORT
WITS
SERIAL
PORT
EXHAUST
PRESSURE SENSOR
SAMPLE INLET
VACUUMSENSOR
CG PRESSURE
SENSOR
SAMPLE PUMP
MOTOR C TRL
ELECTRONIC
FLOW METER
A
UDI O
A
LARM
GEOLO
GRAPH
MULTI
FUNCTION
CONTROL
KNOB
USB INTERFACE
4GB SD Card Interface
USB Key Drive Interface
1V FULL SCALE
0.1V FULL SCALE
0.01V FULL SCALE
A
LARM DRY RELAY CONTACT
GEOLOGRAPH DRY RELAY CONTACT
RS232 USB B RS2 32 RS422
TW ISTED
PAIR
ELECTRICALLY ISOLATED
CG SAMPLE
REL AY
Chromatography Pump
Sample Pump
CHROMATOGRAPHY COLUMN
TRAVEL
SAMPLE
SAMPLE IN
CG EXHAUST
SAMPLE EXHAUST
BLOODHOUND FUNCTIONAL OVERVIEW
12 VDC POWER
PORT
1. OVERVIEW – IBALL INSTRUMENTS BLOODHOUND
The Bloodhound Gas Detection and Chromatograph system was developed using digital signal processing
techniques and the very latest in infrared and chemical sensor gas detection. Couple that with multiple
integrated WITS interfaces, filtered and positive pressure inner case cooling, DC power support, a robust
power system, and battery backup makes this system unique in the industry. Further, this new product
integrates 3G wireless technology, Ethernet connectivity with an embedded switch to provide real-time
monitoring and charting via the Internet anywhere in the world.
The Bloodhound
is composed of an infrared detector, a proprietary chromatograph system, medical grade
10,000 hour brushless vacuum pumps, an aircraft grade flow meter, an uninterruptible power system, DC
power input/output port, WITS (Wellsite Information Transfer Specification) communication, Ethernet
connectivity, a wireless 3G data modem and the proprietary digital signal processing system Brain Board and
housed in a rugged plastic Pelican case.
The Bloodhound wireless gas detection equipment has the capability to detect from 0 to 10,000 gas units.
This translates as 0 to 100% typical naturally-occurring hydrocarbon gas mixtures in air. Calibration is
performed using National Institute of Standards and Technology (NIST) traceable calibration gases.
Lab calibration points include 0%, 2.5%, and 100% pure methane. Complete immunity to saturation or
damage in the presence of high concentrations of both light and heavy hydrocarbon gases precludes the
necessity of constant re-calibration or zero referencing.
The briefcase-sized design also has the ability to pull a sample apart using our proprietary temperature –
controlled and integrated gas chromatograph. This chromatograph has been shown to pull the samples apart
in about five (5) to eight (8) minutes depending on the customer controlled temperature setting; the lower the
temperature the longer the time. Typically, chromatograph readings are available in 3.5 to 8 minutes
depending on the degree of separation desired by the customer.