Specifications
Copyright 2014 Carl Bright Inc. All Rights Reserved
Page 38
3> The last comma delineated item is the simple checksum, it will always have a C preceding the ASCII 8 bit
number.
Bloodhound ERROR Number Codes In the Error Field
In the Bloodhound packet, one of the fields is for error (condition) number codes. This number(s) represents
the current condition or conditions and notification of instance that needs to take place such as a blocked
sample line. Below is a table that shows the currently transmitted conditions and the corresponding error
(condition) code number. More than one condition can be present, and if so, are separated by a space.
Condition Code Associated Bloodhound Register Setting
No Alarm 0
Blocked Sample Line 2 Reg 52: factory setting 200 (means –200 mmHg)
Detector High Voltage 3 No register setting - Automatic from HRM
Detector Voltage Low 4 No register setting - Automatic from HRM (if Primary &
Secondary voltage = 0.010 detector is inoperable
due to flooding)
High Flow Rate 5 Reg 50: factory setting 200 LPH
Low Flow Rate 6 Reg 51: factory setting 20 LPH
Low Power Voltage 7 Set at 11.1 VDC No register setting (AC power lost)
High Amps at Cavitator Conn. 9 Reg 37: factory setting 5 (60-sec average)
Set to 0 to disable
High Temperature in Case 10 Reg 46: factory setting 120 degrees F
Low Temperature in Case 11 Reg 47: factory setting 35 degrees F
High Gas Units 12 Reg 53: factory setting 22 (means 2200 units)
Set to 0 to disable
HRM Warming Up 13 Unit is warming up
Unit In Shutdown Mode 14 No register settings
Geolograph Switch Noise 15 Reg 33: factory setting 180 spikes
Set to 0 to disable
CG Low Pressure 16 Reg 54: factory setting 70 (means 700 mmHg)
Set to 0 to disable
High H2S Reading 17 Reg 56: factory setting 50
Can set from 0 to 200
Set to 0 to disable alarm. To disable data stream set
reg 41 to 0.
Exhaust Blocked (high ex prs) 18 Set to 50 mmHg - No register setting
Low DC port amps 19 If the Cavitator is disconnected
Service is reqired 20 The Bloodhound will require service
Flooded 21 The water detector has detected water in the inlet
Flood override 22 Water has entered the system and service technicians
have overridden the warning
Overhaul 255 Permanent electronics failure, service required
B. WITS Data Fields Packet
The Bloodhound collects and monitors the WITS data that is available while during the drilling process.
The Bloodhound then collects all WITS data and builds a packet. It then sends the formed packet to the host
server. All packets start with common fields and the collected WITS packets are appended to it. The end of
the packet is terminated with a carriage return and line feed.
WITS Packet Example:
^,0008_0107,2008/04/20,13:11:13,189092,01082000.4,01102000.4,0112294.1,01130.0,01
15303.9,01177.9,011911.7,012069.3,01213301.7,0122-
0.2,0123110.8,012477.6,012596.0,0126669.0,0127-3.0,012840.0,
0130396.7,0137213292.0,014011.0,0142584285.1,01436334.5,0144206959.0,01450.0,0150
584285.1,










