User's Manual

When the door detects that the door is unable to travel freely while closing, it will re-
open and attempt to close again. A total of three attempts will be made to clear the
problem before a jam is deemed to have occurred and noted on the LCD display.
Changing Frequencies Between 7K and 10K
If Clock Set and Schedule buttons are pressed simultaneously and held for 2 seconds,
the frequency of the Magnetic Transmission mode will immediately change between 7
kHz and 10 kHz.
Disable and Enable the Pushbuttons
If the Down and Up buttons are pressed simultaneously and held for at least 2 seconds,
the keypad will become disabled. Repeating the process will enable the keypad and
return it to an active state.
A one second tone will sound indicating the change has occurred and a message will
scroll across the display when the pushbuttons have been disabled reading as, “Keypad
Locked”. If any of the keys are pressed while the keypad is locked, a “Keypad Locked”
message will scroll across the LCD display.
Low Battery Indication
The battery voltage is consistently measured once every 4 hours. If the reading is below
4.4 Volts each of the times it is checked within a 24-hour period, the Low Battery alarm
will activate. When this occurs, the pet door will beep and display “LOW BATT” on the
LCD display once every 20 seconds. The audible alarm can be disabled by pressing
any of the keypad buttons. If the audible alarm is disabled, the “LOW BATT” message
will appear on the LCD screen every 2 seconds.