GPIO Line Input Logic     
Name  Pin  Type  Notes   
INPUTS               
ON Command  IN-1  Active Low Input  Turns channel ON
OFF Command  IN-2  Active Low Input  Turns channel OFF & sends 
      100 msec STOP pulse
PREVIEW Command  IN-3  Active Low Input  Turns preview ON
RESET Command  IN-4  Active Low Input  “Turns channel OFF, while not sending 
      a STOP pulse”
READY Command  IN-5  Active Low Input  Illuminates OFF lamp to indicate 
      source’s readiness
OUTPUTS               
ON Lamp  OUT-1 Open Collector to Logic  Illuminates when channel is ON 
    Common Return
OFF Lamp  OUT-2 Open Collector to Logic  Illuminates when channel is OFF 
    Common Return  and READY is active
PREVIEW Lamp  OUT-3 Open Collector to Logic  Illuminates when PREVIEW is ON 
    Common Return
START Pulse  OUT-4 Open Collector to Logic  A 100 msec pulse when the channel 
    Common Return  status changes from OFF to ON
STOP Pulse  OUT-5 Open Collector to Logic  A 100 msec pulse when the channel 
    Common Return  status changes from ON to OFF
GPIO Computer Playback Logic    
Name  Pin  Type  Notes
INPUTS               
ON Command  IN-1  Active Low Input  Turns channel ON
OFF Command  IN-2  Active Low Input  Turns channel OFF & sends 100 msec     
    STOP pulse
PREVIEW Command  IN-3  Active Low Input  Turns preview ON
Not Used  IN-4  Active Low Input  “Turns channel OFF, while not sending 
      a STOP pulse”
READY Command  IN-5  Active Low Input  Illuminates OFF lamp to indicate       
      source’s readiness
OUTPUTS               
NEXT Pulse  OUT-1 Open Collector to Logic  A 100 mS PULSE sent when ON button     
    Common Return  is depressed except when initially 
      turned ON
OFF Lamp  OUT-2 Open Collector to Logic  Illuminates when channel is OFF 
    Common Return  and READY is active
PREVIEW Lamp  OUT-3 Open Collector to Logic  Illuminates when PREVIEW is ON 
    Common Return
START Pulse  OUT-4 Open Collector to Logic  A 100 mS PULSE sent when channel is     
    Common Return  rst turned ON
STOP Pulse  OUT-5 Open Collector to Logic  A 100 mS PULSE sent when channel is     
    Common Return  rst turned OFF