MANUAL Screen Functions
The CT50 has 4 manual override commands. The manual screen is accessed by touching the large
current temperature display in the middle of the HOME screen.
IMPORTANT: The Mode must be in HEAT or COOL to access the manual screen.
TEMPORARY override Touch the + / - arrows to select your desired temporary Target
Temperature. Touch HOME to return to operation. The TEMPORARY icon will display indicating
you have modied the Target Temperature for the current Time Slot only. It goes back to the
program target at the next period. Also, when in TEMPORARY, if the target is set the same as the
programmed target for that period, the word TEMPORARY will go out.
HOLD
This will hold the target temperature you set indenitely, until you turn HOLD off. HOLD will allow
you to operate your thermostat as a manual thermostat. It will keep whatever temperature you set until
you change it or cancel hold. Take care using the HOLD function as the program is now bypassed. To set
a hold target temperature, touch HOLD and use the +/- icons to select your hold temperature. The HOLD
icon will display on the HOME screen indicating you have changed the Target Temperature. The system
will HOLD this temperature until you return to the manual screen and de-select HOLD by touching it. Hold
is also canceled when you set the mode to OFF.
HOLIDAY This is a single program that repeats day after day until you turn it off. It supersedes the