User's Manual

5-8
DrillTrack G2 BoreLogger Instructions
1. Enter set-up Mode and set the BORELOG option to ON.
2. To enter Borelog Mode press and hold the key. A list of functions for the logging will appear:
GO, DEL, END, UPL
Scroll through using the or key, press key to confirm selection.
3. To start a log, set the log to GO.
4. When in the “Four-Arrows Locate” screen with depth displayed. Press the key to transmit
the depth to the Data View. The screen will then display “LOG”, press key again within 5
seconds to confirm. The display changes to a new screen, an audible beep confirms the action of
logging the data, showing “LOG” and the stored rod number
5. To add a simulated locate point, in the “Two Arrow Steering” screen press the key, the
display will show ADD and LOG with a rod number, press key again to confirm the addition
of the simulated locate point.
6. To delete one log back, hold down the key to enter the Borelog Mode.
7. Select DEL and press INFO to delete one log. When finished deleting, press and hold key
and select GO to return to logging data.
9. When finished with logging, it is important that the log is manually ended. Do this by entering
into the Borelog Mode and select END. Upon completion of the Borelog date and time will be
stored.
10. To upload the Borelog data, enter the Borelog Mode and select UPL and press key to
activate the data transfer. A rotating clock will appear to confirm that the unit is waiting to upload
the log to the PC.
11. After uploading is completed, turn off the DrillTrack G2.