DrillTrack Operating Instructions
DataSonde Temperature Alarms
A DataSonde temperature alarm will occur at a temperature of 40
o
C (104
o
F).
The Receiver beeps and will automatically display the information screen for 15 seconds. The DataView
sounder will beep and the LCD will flash the high temperature. Such alarm indication will occur with every 5
o
C
of temperature increase.
When the DataSonde temperature reaches 75°C (167
o
F) both the Receiver and DataView will displayHI” and
NO Tilt angle or Roll position data will be displayed until the DataSonde temperature falls below 4C (104
o
F).
Exceeding of the DataSonde its maximum temperature will permanently damage the DataSonde and will void
any warranty.
The Temperature of the DataSonde is continuously displayed on the DataView at the directional drilling
machine. The DataSonde temperature is also displayed on the information screen of the Receiver.
A temperature overheat indicator is located at the front of the electronics endcover and indicates if the
DataSonde has exceed its maximum operating temperature of 104°C (220
o
F)
temperature has not exceeded its maximum.
temperature has exceeded its maximum.
The DataSonde can also be internally interrogated by a Radiodetection authorized service repair center, to
verify the exact high temperature reached.