Installation Guide

Table Of Contents
RadioFrame System
Equipment Commissioning
RFN_3.1 Beta 101
Cell Reselection (Mobile #)
1
2
3
5.6.1.5 Interconnect Connection Stability and SQE Performance
A single link for 3:1 Interconnect will be maintained for 30 minutes each. The
following table presents the data to be collected for each selected link. The iDEN
Field Test Application (IFTA) shall be used in “Single Cell” mode to observe the
SQE performance and plotted over time.
Table 7 Interconnect Connection Stability
Interconnect #1 Carrier # RSSI (dBm) SQE (dB) Sector Duration (min)
30
Interconnect #2
30
Interconnect #3
5.6.1.6 Dispatch Connection Stability
To verify Dispatch connection stability, a Dispatch (private or group) call will be
maintained for several minutes. The following table presents the data to be
collected for each dispatch call.
Table 8 Dispatch Connection Stability
Dispatch #1 Carrier # RSSI (dB) SQE (dB) Sector Quality
(1-5)
Duration
(min)
3
Dispatch #2
4
Dispatch #3
5
5.6.1.7 Idle SQE Testing and Validation
To validate SQE performance, the following test shall be conducted:
1 Control Channel SQE: