User's Manual

MC-Series System Installation & Testing
Scheduled and Unscheduled Maintenance
RadioFrame Networks, Inc. 73
7.4.4.4 Task Abnormally Terminated
ID: 0004
Service: asp
Severity: major
Cause: S/W Program Abnormally Terminated
System Reaction: System Reset except for RLIC
Additional Info: First 4 ASCII Text characters of the task that suspended
Repair Action: System should recover on its own. However, this alarm should be reported to
RFN for further investigation. Check corresponding board for any connection problems.
7.4.4.5 Spinning task starving system
ID: 0005
Service: asp
Severity: major
Cause: Application Subsystem Failure
System Reaction: System Reset
Additional Info: None
Repair Action: Check corresponding board for any flash corruption. System should recover on
its own. However, this alarm should be reported to RFN for further investigation. Collect target
serial logs.
7.4.4.6 Lost communication with target
ID: 0007
Service: asp
Severity: critical
Cause: Remote Node Transmission Error
System Reaction: System Reset
Additional Info: Peer IP Address
Repair Action: This is a result of lost communication with a target board. Check the
corresponding board for improper insertion, faulty cables, improperly inserted cable.
7.4.4.7 5 MHz clock signal not present
ID: 0008
Service: asp
Severity: critical
Cause: Loss of Signal