User's Manual

MC-Series System Installation & Testing
Scheduled and Unscheduled Maintenance
110 RadioFrame Networks, Inc.
9 In System Manager, refresh the RBS Status page until the RadioBlade icon status bar
changes from red (not present) to yellow (present and locked). This will take approximately
three minutes.
10 Unlock the RadioBlade.
On the RadioBlade Statistics page, the State of the RadioBlade will change from 2 (locked) to 11
(unlocked).
7.9.4.2 Multi Ch 900 RB
TBD
7.9.4.3 Multi Ch 800 RB
TBD
7.9.5 Power Distribution Unit
The Power Distribution Unit (PDU) receives DC input and supplies power via dedicated circuit
breakers to each component in the MC-Series System. Each of the thirteen breakers has a three-
position switch: ON, OFF or TRIPPED. The single alarm output connected to each breaker is
normally closed, and goes open when a breaker is tripped.