Repair Action: Re-download the software load lineup to the RLIC and reset system. This alarm
should only occur after a software download and a reset to that partition.
7.4.4.25 RF Shelf External Alarm Major
ID: 0038
Service: asp
Severity: Major
Cause: Equipment Malfunction
System Reaction: No action taken
Additional Info: RBS Group Number
Repair Action: Replace the RF shelf reporting the alarm. Connect serially to the RF shelf to
further isolate the specific failure.
7.4.4.26 RF Shelf External Alarm Minor
ID: 0039
Service: asp
Severity: Minor
Cause: Equipment Malfunction
System Reaction: No action taken
Additional Info: RBS Group number
Repair Action: Replace the defective fan on the back of the RF shelf unit.
7.4.4.27 LAPD connection to ISC failed
ID: 4097
Service: iden
Severity: critical
Cause: Local Node Transmission Error
System Reaction: BR Disabled
Additional Info: minor state 1..15
Repair Action: Check connection to ISC. Check ISC status. Can also be caused by another
RFN system sharing the same connection to the ISC if its BR’s are configured the same.
7.4.4.28 Lost comm. With iDEN RadioBlade
ID: 4098