User's Manual

MC-Series Standard Capacity system
998-1019-01 Rev X1
8-4 ©2008 RadioFrame Networks, Inc. MC-Series
Proprietary and Confidential Information
8.3.3 DRBS Indicators
Table 8.2 DRBS LED Indications
8.3.4 RF Shelf Indicators
LED Indication Condition Corrective action
STATUS
green normal condition none
not lit no power to DRBS
Verify that DRBS circuit breaker on
PDU is ON.
Check power connection to PDU.
Measure power input, and compare
with tolerances listed in section
Chapter 2 (Specifications),
Verify that the power source is
operational.
Contact the TAC: (800) 328-0847
red
timing is not synchronized to
the group (A, B, or C)
Board unable to boot
Power cycle the DRBS using the
circuit breaker on the PDU.
Contact the TAC: (800) 328-0847
RADIOBLADE
TRANSCEIVER
STATUS
green
RadioBlade transceiver
present and operational
none
not lit
RadioBlade transceiver not
present
none
RadioBlade transceiver
present
Reseat RadioBlade transceiver.
red
RadioBlade transceiver is in
error state
Reseat RadioBlade transceiver.
If still red, replace RadioBlade
transceiver.