User's Manual

MC-Series Standard Capacity system
998-1019-01 Rev X1
MC-Series ©2008 RadioFrame Networks, Inc. E-1
Proprietary and Confidential Information
Appendix E BER Test Procedure
E.1 Bit Error Rate (BER) Diagnostic Test
The Bit Error Rate (BER) Diagnostic Test is used to execute BER tests of the MCSC
system. The Diagnostic Test supports multi-channel RadioBlade (MCRB)
transceivers in the 800E MHz band. BER testing gives a pass/fail determination for
each blade and should be performed on all blades in the Diversity RadioBlade shelf
(DRBS).
The most common testing scenario involves acceptance-test plan (ATP) execution
during incoming inspection and commissioning. The MCSC system can be taken out
of service for testing during a maintenance window. The RadioBlade transceivers
can be locked as a group and then unlocked one-by-one for the BER tests.
E.2 Prerequisites for Testing
These procedures presume that the MCSC system is in place at its site of service
and operational. Therefore, the prerequisites for operation will already have been
satisfied:
The T1/E1 is live and has been tested.
The datafill has been completed, including BR cabinet and position
assignments, and conforms to the recommended datafill.
All site cabling and installation work has been completed and all punchlist items
corrected.
The system is powered and operational.
The software is at least Revision 14.x.xxx.
In addition, the following conditions are required for BER testing:
The BER test requires that the RadioBlade Shelf be connected to an ISC.