MC-Series ©2008 RadioFrame Networks, Inc. 5-7
Proprietary and Confidential Information
MC-Series Standard Capacity system998-1019-01 Rev X1
Figure 5.5 iDEN Configuration Page
8. After iDEN configuration is updated (by clicking on Save Changes), a System
Reset is required. (Refer to section 3.4 (iDEN Configuration) if necessary.
9. Go to the Performance Monitoring page (section Local Performance Monitoring
“Local Performance Monitoring”) and confirm that are BRs that were intended to
be brought up are in the UEA state. If there are BRs that are not active, select
the
Alarms tab and review the Active Alarm Manager for any active alarms.
For more information, refer to section 8.4.3 (System Manager Alarms).
10. Validate ToR output power or go to step 12 .
11. Connect the General Dynamics R2660 Series Communication System Analyzer
to the rear of the enclosure Tx /Rx1. Then set up the R2660 for iDEN Base
mode. Enter the control channel frequency for sector 1, and then measure the
output power of that frequency.