User's Manual

70
accommodated.
Both adjustments may be inhibited if not desired.
Both adjustments may also be set to NULL, temporarily turning off the knob but maintaining the last
memorized setting.
Adjustments may be memorized and then the knobs returned to center point to use that amount of
adjustment, allows easy use of the trimming knobs for multiple models. (Note that when memorization is
repeated with the knob offset from center, the trim value accumulates.)
Adjustments are quickly reset to the initial value by turning the dial until the trim reads 0%, memorizing,
then returning the knob to its center position.
Note that all functions, including these, assume the model hovers at half stick.
•Available i n normal (NORM) or normal/ idle-up1 (NORM/IDL1) condition only.
Goals Steps Inputs
Fine-tun e hovering with th e hovering
adjustments. Remember these affect
only the hovering (normal) condition.
Adjust throttle and collective pitch
curves until model hovers nicely. In
flight,adjust collective pitch and
throttle
curves near hover point independently
with
HOV-THR
and
HOV-PIT
knobs.
Store ne w settings after flight.
Open the
HOV-THR
function
to BASIC. again to
ADVANCE
,
to HOV-THR.
Optional: chan ge which
knob adj u st
seac h hovering
cu rv e.
NULL
lo c k s in
curve
in last stored position.
to VR to desired knob and
direction
Close
Open the
HOV-PIT
function.
to HOV-PIT. Repeat.
Close
5.3.6 HIGH/LOW PITCH (HI/LO-PIT):
This function may be used to adjust the curves high and low side individually for each flight condition
(normal, idle-up 1, idle-up 2, idle-up 3, throttle hold).
ADJUSTABILITY:
You may define high and low side rate trim knobs (the high side pitch trim control is defined as the right
side lever at initial setting).
The conditions are activated in the CONDITION SELECT function.
Both adjustments may be set to MANUAL, temporarily turning off the knob.
Adjustments may be memorized and then return the knobs to center point to use that amount of adjustment,
allows easy use of the trimming knobs for multiple models.
Goals Steps Inputs
Set up a high pitch curve
in the idle-up 1condition.
Open the HI/LO-PIT
to BASIC menu, again to ADVANCE menu.
to HI/LO-PIT.