RPc, GPc, XPc, XR Series Installation Instructions IN096 Rev A 0718 3 Saber Way, Ward Hill, MA 01835 | radonaway.
Fan Installation & Operating Instructions RPc, GP,c XPc, XR Series Fans Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE TO FAN IS LOCKED IN “OFF” POSITION. DISCONNECT POWER BEFORE SERVICING FAN. 1. WARNING! For General Ventilating Use Only. Do Not Use to Exhaust Hazardous, Corrosive or Explosive Materials, Gases or Vapors. See Vapor Intrusion Application Note #AN001 for important information on VI Applications. RadonAway.
Fan Installation & Operating Instructions RPc Series GPc Series XPc / XR Series RP140c |P/N 23029-1 GP301c | P/N 23006-1 XP201c | P/N 23011-1 RP145c | P/N 23030-1 GP501c | P/N 23005-1 XR261 | P/N 23019-1 RP260c | P/N 23032-1 RP265c | P/N 23033-1 1.0 SYSTEM DESIGN CONSIDERATIONS 1.1 INTRODUCTION The RPc, GPc, XPc and XR Series Radon Fans are intended for use by trained, professional, certified/licensed radon mitigators.
1.7 CONDENSATION & DRAINAGE Condensation is formed in the piping of a mitigation system when the air in the piping is chilled below its dew point. This can occur at points where the system piping goes through unheated space such as an attic, garage or outside. The system design must provide a means for water to drain back to a slab hole to remove the condensation. The RPc, GPc, XPc and XR Series Fan MUST be mounted vertically plumb and level, with the outlet pointing up for proper drainage through the fan.
2.0 INSTALLATION The RPc, GPc, XPc and XR Series Fans can be mounted indoors or outdoors. (It is suggested that EPA and radon mitigation standards recommendations be followed in choosing the fan location.) The GPc fans have an integrated mounting bracket; RPc, XPc and XR Series Fans may be mounted directly on the system piping or fastened to a supporting structure by means of an optional mounting bracket.
THE FOLLOWING CHARTS SHOW THE PERFORMANCE OF THE RPc, GPc, XPc and XR SERIES FANS RPc Series Product Specifications Typical CFM Vs. Static Pressure “WC Model 0” .25” .5” .75” 1.0” 1.25” 1.5” 1.75” 2.0” RP140c 135 103 70 14 - - - - RP145c 166 146 126 104 82 61 41 21 3 RP260c 251 209 157 117 70 26 - - - RP265c 334 291 247 210 176 142 116 87 52 Model Power Consumption 120VAC, 60Hz, 1.
GPc Series Product Specifications Typical CFM Vs. Static Pressure “WC 1.0” 1.5” 2.0” 2.5” 3.0” 3.5” 4.0” GP301c 64 54 41 4 - - - GP501c - - 66 58 50 27 4 Model Power Consumption 120VAC, 60Hz, 1.5 Amp Maximum Maximum Recommended Operation Pressure* (Sea Level Operation)** GP301c 56-100 watts 2.3” WC GP501c 68 - 146 watts 3.8” WC *Reduce by 10% for High Temperature Operation **Reduce by 4% per 1000 ft. of altitude. Model Size Weight Inlet/Outlet GP301c 13”H x 12.5” Dia.
IMPORTANT INSTRUCTIONS TO INSTALLER Inspect the RadonAway® RPc, GPc, XPc and XR Series Fan for shipping damage within 15 days of receipt. Notify RadonAway of any damages immediately. RadonAway is not responsible for damages incurred during shipping. However, for your benefit, RadonAway does insure shipments. There are no user serviceable parts inside the fan. Do not attempt to open the housing. Return unit to factory. (See Warranty below).