Full Product Manual
IN096 REV D 0122 63 Saber Way Ward, Hill, MA 01835 | radonaway.com
Typical CFM Vs. Static Pressure “WC
0” .5” 1.0” 1.5” 1.75” 2.0”
XP201c 112 95 70 40 - -
XR261 217 149 87 27 - -
Model Size Weight Inlet/Outlet
XP201c 9.5”H x 8.5” Dia. 6 lbs 4.5” OD
XR261 9.5”H x 8.5” Dia. 7 lbs 6” OD
Model
Power Consumption
120VAC, 60Hz, 1.5 Amp Maximum
Maximum Recommended Operation Pressure*
(Sea Level Operation)**
XP201c 45 - 66 watts 1.7” WC
XR261 67 - 117 watts 1.6” WC
*Reduce by 10% for High Temperature Operation. **Reduce by 4% per 1000 ft. of altitude.
THE FOLLOWING CHARTS SHOW THE PERFORMANCE OF THE RPc, GPc, XPc AND XR SERIES RADON FANS
XPc and XR Series Product Specications
Typical CFM Vs. Static Pressure “WC
Model 0” .2” .5” .75” 1.0” 1.25” 1.5” 1.75” 2.0”
RP140c 152 120* 64* - - - - -
RP145c 168 150* 123* 105 84* 64 44 20 3
RP260c 251 210* 157 117 70 26 - - -
RP265c 326 290* 241* 207 174* 143 118 89 60
Model Size Weight Inlet/Outlet L.2
RP140c 8.5”H x 9.7” Dia. 5.5 lbs 4.5”OD (4.0” PVC Sched 40 size compatible) 25
RP145c 8.5”H x 9.7” Dia. 5.5 lbs 4.5” OD 15
RP260c 8.6”H x 11.75” Dia. 5.5 lbs 6.0” OD 48
RP265c 8.6”H x 11.75” Dia. 6.5 lbs 6.0” OD 30
Model
Power Consumption
120VAC, 60Hz, 1.5 Amp Maximum
Maximum Recommended Operation Pressure*
(Sea Level Operation)**
RP140c 14 - 19 watts 0.6” WC
RP145c 46 - 72 watts 1.7” WC
RP260c 47- 65 watts 1.3” WC
RP265c 86 - 122 watts 2.2” WC
L.2 = Estimated Equivalent Length of Rigid Metal Ducting resulting in .2” WC pressure loss for Duct Size listed. Longer Equivalent Lengths
can be accommodated at Flows Lower than that at .2” WC pressure loss (see CFM Vs Static Pressure “WC Table).
*Reduce by 10% for High Temperature Operation. **Reduce by 4% per 1000 ft. of altitude.
*Denotes HVI Certied Values.