c RP / RPc Series Installation Instructions IN020 Rev X 0218 3 Saber Way, Ward Hill, MA 01835 | radonaway.
Fan Installation & Operating Instructions Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE TO FAN IS LOCKED IN “OFF” POSITION. DISCONNECT POWER BEFORE SERVICING FAN. 1. WARNING! For General Ventilating Use Only. Do Not Use to Exhaust Hazardous, Corrosive or Explosive Materials, Gases or Vapors. See Vapor Intrusion Application Note #AN001 for important information on VI Applications. See RadonAway.com/vapor-intrusion. 2.
Fan Installation & Operating Instructions RP140 RP145 RP260 RP265 RP380 | | | | | P/N P/N P/N P/N P/N Fan Series 28460 RP140c | P/N 23029-1 28461 RP145c | P/N 23030-1 28462 RP260c | P/N 23032-1 28463 RP265c | P/N 23033-1 28464 1.0 SYSTEM DESIGN CONSIDERATIONS 1.1 INTRODUCTION The RP / RPc Series Radon Fans are intended for use by trained, professional, certified/licensed radon mitigators.
1.7 CONDENSATION & DRAINAGE Condensation is formed in the piping of a mitigation system when the air in the piping is chilled below its dew point. This can occur at points where the system piping goes through unheated space such as an attic, garage or outside. The system design must provide a means for water to drain back to a slab hole to remove the condensation. The RP / RPc Series Fan MUST be mounted vertically plumb and level, with the outlet pointing up for proper drainage through the fan.
1.10 ELECTRICAL WIRING The RP / RPc Series Fans operate on standard 120V, 60Hz AC. All wiring must be performed in accordance with National Fire Protection (NFPA) National Electrical Code, Standard #70, current edition, for all commercial and industrial work, and state and local building codes. All wiring must be performed by a qualified and licensed electrician. Outdoor installations require the use of a UL Listed watertight conduit.
2.3 SYSTEM PIPING Complete piping run using flexible couplings as a means of disconnect for servicing the unit and for vibration isolation. As the fan is typically outside of the building thermal boundary and is venting to the outside, installation of insulation around the fan is not required. 2.4 ELECTRICAL CONNECTION Connect wiring with wire nuts provided, observing proper connections (See Section 1.10). Note that the fan is not intended for connection to rigid metal conduit.
RP / RPc Series Product Specifications The following chart shows fan preformance for the RP / RPc Series Fans: Typical CFM Vs. Static Pressure “WC 0” .25” .5” .75” 1.0” 1.25” 1.5” 1.75” 2.0” RP140/140c 135 103 70 14 - - - - RP145/145c 166 146 126 104 82 61 41 21 3 RP260/260c 251 209 157 117 70 26 - - - RP265/265c 334 291 247 210 176 142 116 87 52 RP380 531 490 415 340 268 200 139 84 41 Model Power Consumption 120VAC, 60Hz, 1.
IMPORTANT INSTRUCTIONS TO INSTALLER Inspect the RadonAway® RP/RPc, GP/GPc, XR/XRc, XP/XPc, XR and SF Series Fan for shipping damage within 15 days of receipt. Notify RadonAway of any damages immediately. RadonAway is not responsible for damages incurred during shipping. However, for your benefit, RadonAway does insure shipments. There are no user serviceable parts inside the fan. Do not attempt to open the housing. Return unit to factory for service.