Typical CFM Vs. Static Pressure “WC
0” .25” .5” .75” 1.0” 1.25” 1.5” 1.75” 2.0”
RP140/140c 135 103 70 14 - - - -
RP145/145c 166 146 126 104 82 61 41 21 3
RP260/260c 251 209 157 117 70 26 - - -
RP265/265c 334 291 247 210 176 142 116 87 52
RP380 531 490 415 340 268 200 139 84 41
Model Size Weight Inlet/Outlet L.2
RP140/140c 8.5”H x 9.7” Dia. 5.5 lbs 4.5”OD (4.0” PVC Sched 40 size compatible) 25
RP145/145c 8.5”H x 9.7” Dia. 5.5 lbs 4,5” OD 15
RP260/260c 8.6”H x 11.75” Dia. 5.5 lbs 6.0” OD 48
RP265/265c 8.6”H x 11.75” Dia. 6.5 lbs 6.0” OD 30
RP380 10.53”H x 13.41” Dia. 11.5 lbs 8.0” OD 57
Model
Power Consumption
120VAC, 60Hz, 1.5 Amp Maximum
Maximum Recommended Operation Pressure*
(Sea Level Operation)**
RP140/140c 15 - 21 watts 0.7” WC
RP145/145c 41 - 72 watts 1.7” WC
RP260/260c 47-65 watts 1.4” WC
RP265/265c 91 - 129 watts 2.2” WC
RP380 96 - 138 watts 2.2” WC
L.2 = Estimated Equivalent Length of Rigid Metal Ducting resulting in .2” WC pressure loss for Duct Size listed. Longer Equivalent Lengths
can be accommodated at Flows Lower than that at .2” WC pressure loss (see CFM Vs Static Pressure “WC Table).
Recommended Ducting: RP/RPc Series Fans (excluding RP380), 3” or 4” Schedule 20/40 PVC Pipe;
RP380, 6” Schedule 20/40 PVC Pipe
PVC Pipe Mounting: If used for Ventilation, use 4”, 6” or 8” Rigid or Flexible Ducting.
Mount on the duct pipe or with optional mounting bracket.
Storage Temperature Range: 32-100 degrees F
Thermal Cutout:
Continuous Duty
Class F Insulation (RP140/RP140c Class B)
Thermally Protected Auto Reset
3000 RPM
Rated for Indoor or Outdoor Use
*Reduce by 10% for High Temperature Operation **Reduce by 4% per 1000 ft. of altitude.
The following chart shows fan preformance for the RP / RPc Series Fans:
RP / RPc Series Product Specications
RP140/140c 130
o
C (266
o
F)
RP145/145c 150
o
C (302
o
F)
RP260/260c 150
o
C (302
o
F)
RP265/265c 150
o
C (302
o
F)
RP380 150
o
C (302