The World’s Leading Radon Fan Manufacturer RP Series Installation & Operating Instructions RadonAway 3 Saber Way Ward Hill, MA 01835 www.radonaway.
DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE TO FAN IS LOCKED IN "OFF" POSITION. DISCONNECT POWER BEFORE SERVICING FAN. 1. 2. 3. 4. 5. WARNING! WARNING! For General Ventilating Use Only. Do Not Use to Exhaust Hazardous, Corrosive or Explosive Materials, Gases or Vapors. See Vapor Intrusion Application Note #AN001 for important information on VI applications. RadonAway.
INSTALLATION & OPERATING INSTRUCTIONS IN020 Rev R RP Series RP140 RP145 RP260 RP265 RP380 p/n 23029-1 p/n 23030-1 p/n 23032-1 p/n 23033-1 p/n 28208 1.0 SYSTEM DESIGN CONSIDERATIONS 1.1. INTRODUCTION The RP Series Radon Fans are intended for use by trained, professional, certified/licensed Radon mitigators. The purpose of this instruction is to provide additional guidance for the most effective use of an RP Series Fan.
1.7. CONDENSATION & DRAINAGE Condensation is formed in the piping of a mitigation system when the air in the piping is chilled below its dew point. This can occur at points where the system piping goes through unheated space such as an attic, garage or outside. The system design must provide a means for water to drain back to a slab hole to remove the condensation. The RP Series Fan MUST be mounted vertically plumb and level, with the outlet pointing up for proper drainage through the fan.
1.9. VENTILATION If used as a ventilation Fan any type of ducting is acceptable, however, flexible nonmetallic ducting is recommended for easy installation and quieter operation. Insulated flexible ducting is highly recommended in cold climates to prevent the warm bathroom air from forming condensation in the ducting where it is exposed to colder attic air. The outlet of the fan should always be ducted to the outside. Avoid venting the outlet of the fan directly into an attic area.
2.1 MOUNTING Mount the RP Series Fan vertically with outlet up. Insure the unit is plumb and level. When mounting directly on the system piping assure that the fan does not contact any building surface to avoid vibration noise. 2.2 MOUNTING BRACKET (optional) The RP Series Fan may be optionally secured with the RadonAway P/N 25007 (25033 for RP385) mounting bracket. Foam or rubber grommets may also be used between the bracket and mounting surface for vibration isolation. 2.
RP SERIES PRODUCT SPECIFICATIONS The following chart shows fan performance for the RP Series Fan: Typical CFM Vs Static Pressure "WC 0" .25" .5" 135 103 70 RP140 RP145 166 146 126 RP260 272 220 176 RP265 334 291 247 RP380* 497 401 353 * Tested with 6” inlet and discharge pipe. Power Consumption 120 VAC, 60Hz 1.5 Amp Maximum RP140 17 - 21 watts RP145 41 - 72 watts RP260 52 - 72 watts RP265 91 - 129 watts RP380 95 - 152 watts .75" 14 104 138 210 281 1.0" 82 103 176 220 1.25" 61 57 142 176 1.
IMPORTANT INSTRUCTIONS TO INSTALLER Inspect the GP/XP/XR/RP/SF Series Fan for shipping damage within 15 days of receipt. Notify RadonAway® of any damages immediately. RadonAway® is not responsible for damages incurred during shipping. However, for your benefit, RadonAway® does insure shipments. There are no user serviceable parts inside the fan. Do not attempt to open. Return unit to factory for service.