Instructions / Assembly

!
RP SERIES PRODUCT SPECIFICATIONS
The following chart shows fan performance for the RP Series Fan:
Typical CFM Vs Static Pressure "WC
!
0"
.25"
.5"
.75"
1.0"
1.25"
1.5"
1.75"
2.0"
RP140
135
103
70
14
-
-
-
-
-
RP145
166
146
126
104
82
61
41
21
3
RP260
272
220
176
138
103
57
13
-
-
RP265
334
291
247
210
176
142
116
87
52
RP380*
497
401
353
281
220
176
130
80
38
* Tested with 6” inlet and discharge pipe.
Power Consumption
120 VAC, 60Hz 1.5 Amp Maximum
Maximum Recommended
Operating Pressure* (Sea Level Operation)**
RP140
17 -
21
watts
RP140
0.8"
W.C.
RP145
41 -
72
watts
RP145
1.7"
W.C.
RP260
52 -
72
watts
RP260
1.5"
W.C.
RP265
91 -
129
watts
RP265
2.2"
W.C.
RP380
95 -
152
watts
RP380
2.0"
W.C.
*Reduce by 10% for High Temperature Operation
**Reduce by 4% per 1000 feet of altitude
!
Size
Weight
Inlet/Outlet
L.2
RP140
8.5H" x 9.7" Dia.
5.5 lbs.
4.5" OD (4.0" PVC Sched 40 size compatible)
25
RP145
8.5H" x 9.7" Dia.
5.5 lbs.
4.5" OD (4.0" PVC Sched 40 size compatible)
15
RP260
8.6H" x 11.75" Dia.
5.5 lbs.
6.0” OD
48
RP265
8.6H" x 11.75" Dia.
6.5 lbs.
6.0” OD
30
RP380
10.53H" x 13.41" Dia.
11.5 lbs.
8.0” OD
57
L.2 = Estimated Equivalent Length of Rigid Metal Ducting resulting in .2in WC pressure loss for Duct Size listed. Longer Equivalent Lengths
can be accommodated at Flows Lower than that at .2in WC pressure loss (see CFM Vs Static Pressure "WC Table).
Recommended ducting: 3" or 4" RP1xx/2xx, 6” RP380, Schedule 20/40 PVC Pipe
Mounting: If used for Ventilation use 4", 6" or 8" Rigid or Flexible Ducting
Mount on the duct pipe or with optional mounting bracket.
Storage temperature range: 32 - 100 degrees F.
Normal operating temperature range: -20 - 120 degrees F.
Maximum inlet air temperature: 80 degrees F.
Continuous Duty
Class F Insulation [RP140 Class B]
Class B Insulation
Thermally Protected
3000 RPM
Rated for Indoor or Outdoor Use