Instructions / Assembly

IN020 Rev K Page 5 of 8
1.8 ELECTRICAL WIRING
The RP Series Fans operate on standard 120V 60 Hz. AC. All wiring must be performed in
accordance with the National Fire Protection Association’s (NFPA)”National Electrical Code,
Standard #70”-current edition for all commercial and industrial work, and state and local
building codes. All wiring must be performed by a qualified and licensed electrician. Outdoor
installations require the use of a U.L. listed watertight conduit. Ensure that all exterior electrical
boxes are outdoor rated and properly sealed to prevent water penetration into the box. A means,
such as a weep hole, is recommended to drain the box.
1.9 SPEED CONTROLS
The RP Series Fans are rated for use with electronic speed controls, however, they are generally
not recommended. If used, the recommended speed control is Pass & Seymour Solid State Speed
Control Cat. No. 94601-I.
2.0 INSTALLATION
The RP Series Fan can be mounted indoors or outdoors. (It is suggested that EPA
recommendations be followed in choosing the fan location.) The RP Series Fan may be mounted
directly on the system piping or fastened to a supporting structure by means of optional
mounting bracket.