Operation Manual

22
User x:
Mo _ _ : _ _ _ _ : _ _ _ _ : _ _ _ _ : _ _ _ _ : _ _ _ _ : _ _
Tu _ _ : _ _ _ _ : _ _ _ _ : _ _ _ _ : _ _ _ _ : _ _ _ _ : _ _
We _ _ : _ _ _ _ : _ _ _ _ : _ _ _ _ : _ _ _ _ : _ _ _ _ : _ _
Th _ _ : _ _ _ _ : _ _ _ _ : _ _ _ _ : _ _ _ _ : _ _ _ _ : _ _
Fr _ _ : _ _ _ _ : _ _ _ _ : _ _ _ _ : _ _ _ _ : _ _ _ _ : _ _
Sa _ _ : _ _ _ _ : _ _ _ _ : _ _ _ _ : _ _ _ _ : _ _ _ _ : _ _
Su _ _ : _ _ _ _ : _ _ _ _ : _ _ _ _ : _ _ _ _ : _ _ _ _ : _ _
2.1.5 I.T.C.S function
The Intelligent Temperature Control System will activate your
installation in advance to assure the desired temperature at the hour
programmed following your weekly program.
This automatic control system works in the following way:
When you start your thermostat for the first time, it will measure the
time taken by your installation to reach the set temperature. The
thermostat will re-measure this time at each program change to
compensate external temperature change & influence. You can now
program your thermostat without the need to adjust the temperature
in advance because your thermostat does it automatically for you.
Select the line with the arrow cursor and Press (Ok) to choose “Yes
or “no”.
Note:
- The maximum time of the ITCS anticipation will be 2 Hours.
- To have a better anticipation, it will be better to disable the ITCS
function when you have small step duration in the programme.
- You can see the start up of this function on the status line in the
main screen. (Small logo ITCS will be blink)
Zones TH1
Rename
Working Mode
Program
ITCS No
Cooling Function yes
1