To enter in the installation menu move the navigation cursor on the
Installation” line and press (OK).
4.3.1 Regulation Sensor
In this submenu you must choose the sensor which will be used for
the regulation of the room managed by the programmer thermostat.
To change the sensor, move the navigation cursor in front of the
desired line and Press (Ok) to valid “”.
Ambient:
- The main zone programmer will regulate the temperature in the
room with this internal sensor.
Floor (ext): (external sensor is needed 10k at 25°C)
- The external sensor is used as floor sensor to regulate the
temperature of the floor.
- The external sensor is used as deported ambient sensor to regulate
the temperature of the room.
Amb. + Limit 1 (external sensor is needed 10k at 25°C)
- The main zone programmer will regulate the temperature in the
room with the internal sensor the external sensor is used as floor
limiter.
- Two new values will be appears:
Lower limit: 18.0°C (default value)
The floor will never decrease under this value.
Higher limit: 35°C (default value)
The floor will never overpass this value.
Regulation Sensor
Ambient
Floor (ext)
Amb. + Limit 1
Amb. + Limit 2
Combined 1
...
Installation
Regulation Sensor
Regulation type
Calibration sensor
Pump exercise