c) Now the thermostat will send the learning message to the
MASTER-RF, Check the good reception on the MASTER-RF,
- 2 squares scrolls on the graphic scope indicate a correct
RFsignal.
- The LED previously selected (in RED) must now shine in
green to indicate that the zones are correctly configured with
the thermostat.
- You can now switch off the thermostat to avoid perturbation
during the installation of the other thermostats.
d) Only when you have finished the configuration of all
thermostats with the MASTER-RF.
Choose the zone(s) which must be managed by the main zone
programmer. (see point a))
On the main zone programmer go to the “RF installation
submenu, and press (OK) to accede to this display,
e) Select the line “init Master A” and press (OK), then the
following screen must be appear,
f) - The main zone programmer will be learned with the MASTER-
RF and it will receive in the same time all information of the RF
installation.
RF installation
init Master A
Init Master B
View
Init Master A