Indications:
Error on the limiter (floor) sensor
Er” will be blinks under the floor sensor house icons ( )
Lower limitation (floor sensor)
Lo will be blinks under the floor sensor house icons ( )
Higher limitation (floor sensor)
Hi” will be blinks under the floor sensor house icons ( )
7 Divers
7.1 Corresponding value for sensors (NTC 10K)
To be check with an Ohmmeter, only when the sensor is
disconnected
0°C / 32°F ~32 KΩ
5°C / 41°F ~25 KΩ
10°C / 50°F ~19,7 KΩ
15°C / 59°F ~15,6 KΩ
20°C / 68°F ~12,5 KΩ
25°C / 77°F ~10 KΩ
30°C / 86°F ~8,1 KΩ
35°C / 95°F ~6,5 KΩ
40°C / 104°F ~5,4 KΩ
7.2 Memory safe
- All volatile memories (Hours, Date) are saved in case of power
supply lost during 4 hours. To have a maximum time save your
product must be plug-in during minimum 1 day.
- All others parameters (installation, program…) are saved all the
time (infinite memory save)