Operation Manual

6
MAIN CHARACTERISTICS
Flush Mounting version, standard fixing with 60mm axes.
Wireless communication (868Mhz)
Large graphic display with backlight
Easy use interface (5 keys with scroll menu).
Rename function (for zones and Masters).
Several languages available
Graphic view for program with icons to help the creation.
Available for Heating & cooling installations (with reversible heat
pump)
Residual humidity supervision
Possibility to regulate on:
- Air sensor only
- Floor sensor only
- Air & Floor combined with different possibilities.
Temporary override function (2H)
Sensors Auto checks (Short circuit and breaks)
Permanent memory storage
TECHNICAL CHARACTERISTICS
Measured temperature precision
0.1°C
Operating temperature
0°C - 50°C
Setting temperature range
5°C - 35°C by 0.5°C step
Regulation
characteristics
- Hysteresis (ON/OFF)
- Proportional Integral (PWM)
Electrical Protection
Class II - IP30
Power Supply
Product consumption:
230V +/- 10% 50Hz
~ 1.8W
Radio frequency
Certification
868 Mhz < 10mW
EN 300220-1, -2
EN 301489-1, -3
Software version
Displayed during the init (after
power supplying)
Version 1.x x