4. SMALL DESCRIPTION
This controller (Receiver + Master) with the main zone programmer are a complete package to manage all
component of your water floor heating and cooling installation.
You could control different type of installations:
Installation1: Heating only.
Installation2: Cooling Only
Installation3: Separate systems (Boiler and water chillers) or slave heat pump.
Installation4: Reversible Heat pump (manual or automatic)
Installation5: Reversible Heat pump (without Heat & Cool information and control)
In case of cooling function is used, you could control the residual humidity in the house by:
The special input on the receiver which can be use for a NTC or Humidity sensor mounting on incoming pipe of
the manifold or a special humidity sensor (see the wiring diagram).
5. LED EXPLANATION
Keyboards:
Validation key (OK)
Plus key (+)
Minus key (-)
Navigation key left (◄)
Navigation key right (►)
Display:
Humidity drier output activated.
1. Comfort mode indicator.
2. Reduced mode indicator.
3. Anti-freeze mode indicator.
4. Heating mode indicator (blinks when operating).
5. Cooling mode indicator (blinks when operating).
6. Room temperatures indicator.
7. Current zone or Room temperature if 7 displayed.
8. Radio frequency graphic.
9. Setting temperature required by the zone thermostat
Or floor temperature if floor sensor is used and 7 displayed.
Special displaying:
FL.l: Indicate that the zone thermostat is in « Floor Lower limitation mode »
FL.h: Indicate that the zone thermostat is in « Floor upper limitation mode »
(Only available if floor sensor is connected)
OFF: Indicate that the thermostat is stopped.
LED 1: Red => Heating demand indication
Red blinking => Heat & cool sensor error
Green => Cooling demand indication
Green Blinking => Humidity detection (Humidity drier is activated)
Off => System in standby
LED 2: Orange => Pump running indicator
LED 3 to 6 (or Led 14 with 2 slaves):
Green Flash: => indicates a correct radio reception on zone.
Green blinking: => - In normal functioning if you press one key indicates the current zone or group zone
selected.
Red: =>Indicates that the zone is activated (Water circulation on this circuit)
Red blinking: Indicates that this zone is in radio reception alarm. The RF thermostat radio signal has
been lost.
(See Radio reception alarm section).