Operation Manual
6
6. INSTALLATION MENU
In order to enter in the installer menu, press the (OK) key during 10 seconds, then the following screen with the
software version must be appear:
How to change a parameter value?
Once the parameter is displayed, press the (OK) key to edit the value, then you can adjust it with (-) or (+) keys.
Press (OK) or wait few seconds to valid your adjustments.
How to exit the installer menu?
To exit the parameter menu, go to the parameter “End” and press (OK).
Names
Description
Default setting & Other possibility
Software version
Radio configuration mode (see the corresponding section)
Type of degrees displayed
°C: Celsius degrees.
°F: Fahrenheit degrees.
Actuator type
NC: Normally closed actuator.
NO: Normally open actuator.
Type of the Heating &
Cooling commutation
Winter / Summer
If 2 Masters are
installed in the house, only
one Master must be use this
function (CtaC or SenS).
The second Master will be
always adjusted on « rF ».
rF: The Heating & Cooling mode will be done by the RF
main zone programmer.
* Generally use when separate system is installed. (Boiler,
water chillers...)
CtAC: The Heating & Cooling mode will be done by the
Heat Pump connected on the special input of your RF
receiver (see the wiring for more explanation)
* Generally use when manual or automatic reversible
Heat pump
SEnS: The heating & Cooling mode will be done by the
sensor installed on the incoming pipe of the manifolds and
connected on the special input on RF receiver (see the
wiring for more explanation) * Generally use when
reversible heat pump without Heat & Cool information and
control is installed.