User manual
Table Of Contents
- 1. BASIC INFORMATION
 - 2. TRANSPORT AND STORAGE
 - 3. UNPACKING, INSTALLATION AND COMMISSIONING
 - 4. GETTING STARTED
 - 5. BALANCE LEVELING
 - 6. MENU STRUCTURE
 - 7. WEIGHING
 - 8. BASICS ON TERMINAL AND SOFTWARE OEPRATION
 - 9. BALANCE SOFTWARE
 - 10. BALANCE ADJUSTMENT
 - 11. DISPLAY CALIBRATION
 - 12. BALANCE USER SELECTION
 - 13. PERIPHERALS
 - 14. ABOUT
 - 15. COMMUNICATION
 - 16. UPDATE
 - 17. LEVELING
 - 18. BALANCE ADAPTATION – USER SETTINGS
- 18.1. Adding a new operator
 - 18.2. Deleting a operator
 - 18.3. Selecting a operator
 - 18.4. Operator settings
 - 18.5. Quick access to determining working modes parameters
 - 18.6. Parameter of working mode WEIGHING – quick access keys
 - 18.7. Parameter of working mode WEIGHING – information
 - 18.8. Parts Counting
 - 18.9. Checkweighing
 - 18.10. Dosing
 - 18.11. Percent setup
 - 18.12. Animal weighing
 - 18.13. Density of solids, liquid and air
 - 18.14. Formulations
 - 18.15. Statistics
 - 18.16. Mass Comparison
 - 18.17. Differential weighing
 
 - 19. ACCESS TO BALANCE PARAMETERS
 - 20. TECHNICAL DATA
 - APPENDIX A – cooperation with EPSON printer
 - APPENDIX B – cooperation with KAFKA printer
 - APPENDIX C – cooperation with label printer CITIZEN
 - APPENDIX D – databases
 

- 74 - 
Temporary custom target mass values 
PROCEDURE: 
o press Quick access key 
o which opens a screen with a field 
for entering the value of target 
mass 
o press field with the value of 
target mass and using a numeric 
keyboard enter the its value.  
Caution: 
The values are rounded to the value of 
balance reading interval. 
Numeric keyboard – description of 
buttons: 
 - DEL: delete last digit 
 - C: delete all digits 
 - OK. accept entered value 
o After returning to weighing, the 
display indicates value of the 
target mass preceded with 
MINUS sign (i.e. value to be 
filled to reach the target mass) 
o Dose the product until the 
indicated mass value is 0.0g  
o The dosing process may be 
aided by a bargraph representing 
current amount of dosed product 
o The workspace area provides 
data on the target mass value 
and current mass of dosed 
product 
Caution: 
The result is recognized as correct if it is within +/- 10% tolerance of the target mass 
value. 
Adding temporary custom target mass values to the database 
If the temporary target mass values are in use, they can be 
saved in the database from the level of main menu. 
PROCEDURE: 
o press Quick access key “DATABASE OF TARGET MASS 
VALUES” 
o to open the content of the Database 
o press „ADD” pictogram 
o enter name of a record and accept it by pressing ENTER 
button. 
o the record with custom target mass is saved in the last 
database entry. 