User manual
Table Of Contents
- 1. BASIC INFORMATION
- 2. TRANSPORT AND STORAGE
- 3. UNPACKING, INSTALLATION AND COMMISSIONING
- 4. GETTING STARTED
- 5. BALANCE LEVELING
- 6. MENU STRUCTURE
- 7. WEIGHING
- 8. BASICS ON TERMINAL AND SOFTWARE OEPRATION
- 9. BALANCE SOFTWARE
- 10. BALANCE ADJUSTMENT
- 11. DISPLAY CALIBRATION
- 12. BALANCE USER SELECTION
- 13. PERIPHERALS
- 14. ABOUT
- 15. COMMUNICATION
- 16. UPDATE
- 17. LEVELING
- 18. BALANCE ADAPTATION – USER SETTINGS
- 18.1. Adding a new operator
- 18.2. Deleting a operator
- 18.3. Selecting a operator
- 18.4. Operator settings
- 18.5. Quick access to determining working modes parameters
- 18.6. Parameter of working mode WEIGHING – quick access keys
- 18.7. Parameter of working mode WEIGHING – information
- 18.8. Parts Counting
- 18.9. Checkweighing
- 18.10. Dosing
- 18.11. Percent setup
- 18.12. Animal weighing
- 18.13. Density of solids, liquid and air
- 18.14. Formulations
- 18.15. Statistics
- 18.16. Mass Comparison
- 18.17. Differential weighing
- 19. ACCESS TO BALANCE PARAMETERS
- 20. TECHNICAL DATA
- APPENDIX A – cooperation with EPSON printer
- APPENDIX B – cooperation with KAFKA printer
- APPENDIX C – cooperation with label printer CITIZEN
- APPENDIX D – databases

- 81 -
18.11.2. Use of reference mass (standard) in weighing.
When carrying out a weighing process, it is possible to use the reference mass
records saved in the Database of Reference Mass (Standards) or define temporary
custom reference mass values.
In case of using the Database of Reference Mass Values it is possible to:
− acquiring mass value to be used
− saving custom temporary reference mass value in the Database of Reference
Mass Values
Caution:
Using Quick Access Keys does not enable deleting reference mass value records from the
database.
Temporary custom reference mass values
PROCEDURE:
o press Quick access key
o which opens a screen with a field for entering the value of
reference mass
o press field with the value of reference mass and using a
numeric keyboard enter the its value.
o
select number of decimal places.
Reference mass value from the DATABASE
PROCEDURE:
o press Quick access key
o to open the content of the Database
o press field with a name of a reference mass value to be
used
o the record is automatically activated for using
o to abandon the record selection and return to weighing:
press working mode pictogram, or
press “Return” arrow.
Caution:
- the balance enables saving a custom temporary reference mass
value in the DATABASE
- press “ADD” pictogram and specify name of a database record using the opened
alphanumeric keyboard