User manual
Table Of Contents
- 1. BASIC INFORMATION
 - 2. TRANSPORT AND STORAGE
 - 3. UNPACKING, INSTALLATION AND COMMISSIONING
 - 4. GETTING STARTED
 - 5. BALANCE LEVELING
 - 6. MENU STRUCTURE
 - 7. WEIGHING
 - 8. BASICS ON TERMINAL AND SOFTWARE OEPRATION
 - 9. BALANCE SOFTWARE
 - 10. BALANCE ADJUSTMENT
 - 11. DISPLAY CALIBRATION
 - 12. BALANCE USER SELECTION
 - 13. PERIPHERALS
 - 14. ABOUT
 - 15. COMMUNICATION
 - 16. UPDATE
 - 17. LEVELING
 - 18. BALANCE ADAPTATION – USER SETTINGS
- 18.1. Adding a new operator
 - 18.2. Deleting a operator
 - 18.3. Selecting a operator
 - 18.4. Operator settings
 - 18.5. Quick access to determining working modes parameters
 - 18.6. Parameter of working mode WEIGHING – quick access keys
 - 18.7. Parameter of working mode WEIGHING – information
 - 18.8. Parts Counting
 - 18.9. Checkweighing
 - 18.10. Dosing
 - 18.11. Percent setup
 - 18.12. Animal weighing
 - 18.13. Density of solids, liquid and air
 - 18.14. Formulations
 - 18.15. Statistics
 - 18.16. Mass Comparison
 - 18.17. Differential weighing
 
 - 19. ACCESS TO BALANCE PARAMETERS
 - 20. TECHNICAL DATA
 - APPENDIX A – cooperation with EPSON printer
 - APPENDIX B – cooperation with KAFKA printer
 - APPENDIX C – cooperation with label printer CITIZEN
 - APPENDIX D – databases
 

- 87 - 
o  non-standard data 
o  non-standard data project 
Each information item features option YES or NO determining its displaying criterion.  
CAUTION: 
Defining non-standard information items is described in chapter 18.8.4. 
Principles for using other buttons related to the DENSITY mode are provided further in 
this user manual. 
Caution: 
Detailed description of procedures on determining density of solids and liquids is provided in 
the USER MANUAL of the density determining kit.
18.13.1. Setting a default function of the density determining mode 
The density mode enables selecting which of its available functions should be 
activated on entering the density determining mode. The selection is made in 
the internal mode settings. Available options: solids or liquids.  
Selecting the default function is 
recommended if the quick access 
buttons for solids / liquids of the 
bottom bar are not used. 
PROCEDURE: 
o in an optional moment press 
grey coloured workspace area 
o to open a screen with all 
available functions and settings 
related to the density mode 
o determine a set of buttons (quick 
access keys) available in the 
bottom bar 
o determine information items to 
be displayed in the workspace 
area  
------------------------------------- 
o scroll to the field Density 
o use the drop down menu to set 
the default mode of the density 
determining function. 