User manual
Table Of Contents
- 1. BASIC INFORMATION
- 2. TRANSPORT AND STORAGE
- 3. UNPACKING, INSTALLATION AND COMMISSIONING
- 4. GETTING STARTED
- 5. BALANCE LEVELING
- 6. MENU STRUCTURE
- 7. WEIGHING
- 8. BASICS ON TERMINAL AND SOFTWARE OEPRATION
- 9. BALANCE SOFTWARE
- 10. BALANCE ADJUSTMENT
- 11. DISPLAY CALIBRATION
- 12. BALANCE USER SELECTION
- 13. PERIPHERALS
- 14. ABOUT
- 15. COMMUNICATION
- 16. UPDATE
- 17. LEVELING
- 18. BALANCE ADAPTATION – USER SETTINGS
- 18.1. Adding a new operator
- 18.2. Deleting a operator
- 18.3. Selecting a operator
- 18.4. Operator settings
- 18.5. Quick access to determining working modes parameters
- 18.6. Parameter of working mode WEIGHING – quick access keys
- 18.7. Parameter of working mode WEIGHING – information
- 18.8. Parts Counting
- 18.9. Checkweighing
- 18.10. Dosing
- 18.11. Percent setup
- 18.12. Animal weighing
- 18.13. Density of solids, liquid and air
- 18.14. Formulations
- 18.15. Statistics
- 18.16. Mass Comparison
- 18.17. Differential weighing
- 19. ACCESS TO BALANCE PARAMETERS
- 20. TECHNICAL DATA
- APPENDIX A – cooperation with EPSON printer
- APPENDIX B – cooperation with KAFKA printer
- APPENDIX C – cooperation with label printer CITIZEN
- APPENDIX D – databases

- 91 -
o Mass of each ingredient is
rounded up or down depending
on the reading interval of a
balance.
o A designed formulation is ready
to use on returning to main
window of the Formulations
mode
o Return to weighing – press
“RETURN” arrow or press field
with working mode pictogram.
Prompts
Enabling prompts (setting their attribute to YES) causes displaying name
of the following ingredients to be weighed. It facilitates the making a
formulation that consists of multiple ingredients.
In case option NO is selected, the data on the following ingredient to be
weighed is not displayed in the WORKSPACE AREA.
18.14.2. Use of database of formulations in weighing.
After enabling the FORMULATIONS mode,
the balance is immediately ready to start
designing a default mixture.
A DEFAULT mixture:
Designing a default mixture is carried out by
highlighting a selection field on the right side
from the formulation name. If the working
mode is changed, and then the user returns to
the formulation mode, the balance
automatically switches to formula making
mode of the default mixture.
PREVIEWING a mixture:
Press field with mixture name to preview list of
ingredients contained in a mixture.
SELECTING a mixture:
Press field between name of a mixture an field
“c”; the formulation is selected for using
a – preview a mixture
b – select a mixture for use
c – set a default mixture
After selecting a formulation, weigh its consecutive ingredients. After stabilizing on
mass indication press OK button. Mass of each ingredient is zeroed after accepting it
by pressing OK button, i.e. it is saved in the formula making process, as mass of a
weighed ingredient.
Press C button to cancel all processes related to formula making process. It also
enables selecting other mixture to be prepared on a balance.