GND IN 
9 
OUT 1 
10 
OUT 2 
11 
OUT 3 
12 
OUT 4 
13 
OUT 5 
14 
OUT 6 
15 
OUT 7 
16 
OUT 8 
17 
COMMON 
(18) YELLOW GREEN 
34.3.  WE 4 - 4 inputs / 4 outputs module 
WE 4 module comprises 4 optoinsulated inputs and 4 optoinsulated 
outputs of reed relays, does not require installing additional modules on the 
main board of the terminal. The input / output wires are led out via a gland 
on the back wall of the housing (3m length). 
34.3.1. Technical specification 
Parameters of outputs 
Quantity of outputs  4 
Type of outputs  Reed operation contacts 
Wire diameter  0,14 - 0,5mm
2
Maximal load-current contact 
capacity 
0,2A DC 
Maximal forward voltage  50V DC 
Parameters of inputs 
Quantity of inputs  4 
Input type  Optoinsulated 
Wire diameter  0,14 – 0,5mm
2
Control voltage range  5 -24V DC 