User's Manual Part 1

WinLink 1000 Installation and Operation Manual Chapter 4 Configuration
Table
4-2. Typical Transmit Power Limits
Regulation Version Min Tx
[dB]
Max Tx
[dB]
MaxTx at
36 Mbps
[dB]
MaxTx
at
48 Mbps
[dB]
Power
Control
F58 4 16 14 10 Yes
F58/EXT 4 16 14 10 Yes
F49 14 15 15 14 No
F53 -3 8 8 8 Yes
F53/EXT 3 3 3 3 No
F24 18 18 18 18 No
FCC
F53HP 10 16 14 10 Yes
F54 2 8 8 8 Yes
F54/ETSI 2 8 8 8 Yes
ETSI
F54-
HG/EXT
-3 3 3 3 Yes
4.7 Defining the Management Addresses
Each site must be configured separately, first site A then site B.
Æ
To define the Management Addresses:
1. Click Configuration from the main menu.
2. Select which site to configure.
The Configuration dialog box opens.
3. Select Management (see
Figure
4-12
).
4. Enter the IP address of the ODU in the IP address field.
Note
If performing configu ation from the WinLink manager, the IP address
is entered in the login screen (
r
Figure 2-4)
5. Enter the Subnet Mask.
6. Enter the Default Gateway.
Defining the Management Addresses 4-21