User's Manual

WinLink User and Installation Guide Version 1.795 6-113
Figure 6-13: Active Alarms Summary
The following table provides an explanation of the command
buttons.
Table
6-6: Active Alarms command buttons
Action
Save Saves the alarms in CSV or text format for further analysis.
Refresh Reads the alarms from the ODU, and displays the alarms.
Site Selects site for the active alarms.
Close Closes the active alarm window.
Remote Power Fail Indication
Remote power fail indication indicates to one side that the other side
has had a power failure. The failed site sends a final trap indication
about the power loss just before powering off.
A Dying-Gasp circuit identifies the power failure at a minimum interval
of 20 milliseconds before the IDU crash, during that interval a message
notifying the power failure is sent to the remote end.
Alarm output number 4 indicates link loss due to power failure at the
remote end.