User's Manual

Chapter 4 Configuration WinLink1000 Installation and Operation Manual
Æ
To configure the Ethernet Mode:
1. From the Configuration menu, select the site to reconfigure.
The Configuration dialog box opens.
2. In the Ethernet Ports Configuration pane, use the drop-down menu
to select the LAN configuration.
3. Click Apply to save the changes.
Note
It is possible to close the Ethernet service by disconnecting the
Ethernet port. The user should be aware that it i possible to close the
port and not have any access to the device. If this should occur the
workaround is as follows:
s
Connect the system from the remote site
Connect via other Ethernet port (IDU-C)
Power down the equipment and connect immediately after the
power up (the fastest way is to enter install mode).
4.12 Changing Community Values
The ODU communicates with the management application using
SNMPv1 protocol. The protocol defines three types of communities:
Read-Only for retrieving information from the ODU
Read-Write to configure and control the ODU
Trap used by the ODU to issue traps.
The community string must be entered at login. The user must know
the password and the correct community string in order to gain access
to the system. A user may have read-only privileges.
It is not possible to manage the ODU if the read-write or the read
community values are forgotten. A new community value may be
obtained from technical support for the purpose of setting new
community; the serial number or the MAC address of the ODU must be
supplied.
4-26 Changing Community Values