User's Manual

WinLink1000 Installation and Operation Manual Chapter 4 Configuration
The manager application and the ODU use the community strings
public-bru1 for the local unit and public-bru4097 for the remote unit.
These are the factory defaults, but can only be used one time on the
first installation.
A new community string must be set when entering the system for the
first time. The read-write community and read-only community have a
minimum of five alphanumeric characters. (Bru1 and bru4097 are not
permitted). Changing the trap community is optional by clicking the
check box.
Note
Editing Community Strings
The community change dialog box is available from the Configuration
> Security tab. Both read-write and read-only communities must be
defined.
On entering for the first time, use netman as the current community.
The community string must be changed when entering the system for
the first time, and the community string netman cannot be used again.
Æ
To change a community:
1. From the Configuration dialog box, select the Security tab
2. Type the current read-write community (default is netman).
3. Select the communities to be changed by clicking the check box.
4. Type the new community and re-type to confirm.
5. Click OK to save.
Changing Community Values 4-27