WinLink1000 Installation and Operation Manual Chapter 5 Diagnostics and Troubleshooting
A: Currently the system provides fixed channels, with one manual
frequency setting. The manual setting provides flexibility of spectrum
selection, including 5.735 MHz.
Q: Can we mange WinLink1000 using SNMPc other than the supplied
management software that comes with the units?
A: Yes. The WinLink1000 is SNMP-based. WinLink1000 can be
managed when using other SNMP software after implementing RADWIN
MIB’s.
Q: Can WinLink1000 be managed and configured via Telnet?
A: No. Use only the WinLink1000 software manager.
Q: Can I use WinLink1000 with any vendor’s external antenna?
A: Yes. RADWIN supplies the WinLink1000 external ODU with an N-
type typical connector. Any vendor’s external antenna that can be
cascaded to our external unit can be used without problem. Please
note that dB losses in the cascading cable between the external ODU
and antenna should be taken into consideration. (In the supplied
cascading cable of one meter we have 1 dB loss)
Q: Do we need to add external arrestors on WinLink1000 cables?
A: The WinLink1000 ODU includes arrestors and lightning protection.
Therefore there is no need to add additional arrestors.
Q: What is the actual Ethernet data rate and maximum throughput?
A: The maximum net throughput of WinLink1000 is full duplex 18
Mbps.
Note
WinLink1000 is a symmetrical system
Q: What is the sensitivity for each rate of the WinLink1000?
A: The rate sensitivities are:
Rate
[Mbps]
Sensitivity
[dB]
12 -84
18 -81
36 -74
Frequently Asked Questions 5-19