User Manual

Maximum Output Power
5725 5850 MHz band - FCC/IC
The maximum output power can be set as follows, when operating in the 5.8 GHz band,
under FCC and IC regulations. The power values are for PtP systems and PtMP systems. For
PtMP systems the total EIRP is limited to 36 dBm. Therefore the output power of the system
will be reduced to comply with 36 dBm EIRP.
RADWIN 2000 JET (PtP)
5 MHz: 29.5 dBm
10 MHz: 29.5 dBm
20 MHz: 29.6 dBm
40 MHz: 29.5 dBm
5250 5350 MHz band FCC/IC
The maximum output power can be set as follows, when operating in the 5.3 GHz band. The
total EIRP limit is 30 dBm.
10 MHz: 5.95 dBm
20 MHz: 9.34 dBm
40 MHz: 9.30 dBm
5470 5725 MHz band FCC/IC
2
The maximum output power can be set as follows, when operating in the 5.3 GHz band. The
total EIRP limit is 30 dBm.
10 MHz: 6.05 dBm
20 MHz: 9.35 dBm
40 MHz: 9.49 dBm
Radiation Exposure Evaluation
RADWIN 2000 JET systems - the calculated recommended safe distance at density of
1mW/cm
2
is 76cm.
RADWIN 5000 JET systems - the minimum separation distance is 20cm
2
Under IC regulations the 5600-5650 MHz band is excluded from operation
RADWIN 2000 JET, RADWIN 5000 JET Reference Guide 2