User's Manual Part 1

Configuration with Telnet Chapter 8
RADWIN 2000 User Manual Release 2.5.40 8-26
Figure 8-23: Telnet session log on
A Read-Only Community string allows display only whereas a Read-Write Community string
allows display and set commands.
Supported Telnet commands are shown in Table 8-2. Note that some of the commands are
model-specific. For example, TDM commands will not apply to Ethernet only and PoE based
links.
Table 8-2: Telnet Commands Summary
Command Explanation
display inventory
Displays ODU product name, Name, Location, hardware and software
revisions, uptime, MAC address, IDU product name, IDU software and
hardware revisions
display management Displays IP, Subnet, Gateway, Traps table
display link
Displays State, Link ID, Channel BW, RSS, TSL, Frequency/ACS, DFS,
Rate/ARA, Distance
display ethernet Displays Bridge Mode, Aging time, Port table (State, Status and action)
display tdm
Displays Clock Mode, Master Clock Mode, Current Clock, Quality, TDM
table (Line status, Error Blocks)
display ntp Displays Time, Server and Offset
display PM <interface:AIR,LAN1,LAN2,TDM1,
TDM2,...,TDM16> <interval:current,day,month>
Shows the performance monitor tables for each interface according to
user defined monitoring intervals
set ip <ipaddr> <subnetMask> <gateway>
Set the ODU IP address, subnet mask and gateway. The user must reset
the ODU after the command completion
set trap <index:1-10> <ipaddr> <port:0-
65535>
Set a specific trap from the traps table (e.g. set trap 3 192.168.1.101
162)
set readpw <oldpasswd> <passwd> Set the read access password (Read Community)
set writepw <oldpasswd> <passwd> Set the read-write access password (Read-Write Community)
set trappw <oldpasswd> <passwd> Set the trap Community string
set buzzer <mode:0=OFF,1 =ON> Toggle the buzzer mode (0 – off, 1 – on)
set tpc<power:Value between minimal Tx power,
and maximal Tx power>
Set the ODU Tx Power. If a wrong value is entered, both min and max
values shall be displayed in the error reply
set bridge <mode:0=Bridging OFF,1= Bridging
ON >
Set the ODU bridge mode (0 – off, 1 – on)
set name <new name> Set the name of the link
set location <new location> Set the name of the location