User's Manual Part 1

Connecting power to the IDU Chapter 3
RADWIN 2000 User Manual Release 2.5.40 3-11
To mount an IDU-C:
1. Attach the rack mounting brackets (K) to the IDU.
2. Bolt the IDU into an empty slot in the rack, ensuring that it sits securely.
3. Ground the IDU to the rack using grounding lug I. The IDU should be left perma-
nently grounded.
Connecting power to the IDU
The IDU-C has redundant power connection circuits (items G and H in Figure 3-10 above).
An enlarged schematic of the power connectors is shown in below:
Figure 3-13: IDU-C Power connectors
The connectors are 3 pin in line female, with polarities (left to right) minus, ground, plus. To
avoid damage to the IDU, always use an AC/DC adapter supplied by RADWIN.
Ensure that the IDUs at both sites are powered up.
The IDU-E has a single three pin power connector, the same as used on the IDU-C.
Table 3-3: IDU-C and New Style IDU-E Front Panel LEDs for HSS
Color Function
Green This ODU is HSS master, generating signal, and HSS Sync is OK
Blinking
Green
This ODU is a HSS client and in Sync
Red HSS not operational due to improper signal detection. This ODU is not transmitting
Orange
HSS is operational. One of the following conditions apply:
This ODU is a master that is generating signals and detecting signals
This ODU is a master that is generating signals but detected improper signals
This ODU is a client “Continue Tx” but is not detecting signals
This ODU is a client “Disable Tx” and is detecting signals from multiple sources
All orange cases transmit.
Off
HSS is not activated
Disconnection between ODU and IDU
Note
Instead of using the rack mounting brackets, the IDU may be rail mounted
using the four screw holes on each of its sides.