RADWIN 6000 Small Cell Base Station REFERENCE GUIDE RELEASE 6.1.
Regulatory Compliance FCC - Compliance This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Warning • Where Outdoor units are configurable by software to Tx power values other than those for which the product is certified, it is the responsibility of the Professional Installer to restrict the Tx power to the certified limits. The RADWIN 6000 band 2 should be installed and operated with a minimum distance of 243 cm (8 ft) between the radiator and any person and RADWIN 6000 band 5 should be installed and operated with a minimum distance of 142 cm (4.
RADWIN 6000 Small Cell Base Station REFERENCE GUIDE RELEASE 6.1.
Chapter 1 Introduction Product Overview RW6000 is a small cell solution that provides (UMTS) HSPA+ services for cellular operators and Broadband Wireless Access (BWA) Services for Internet Service Providers. This compact, carrier grade and fully outdoor unit supports high capacity and high transmission power with remarkably low power consumption. Offering an intelligent and cost effective solution, RW6000 extends remote rural area coverage and expands capacity in dense urban outdoor hotspots.
RADWIN 6000 Chapter 1 Reference and Standards Reference Number Reference Description 3GPP TR 25.820 3G Home Node B (HNB) study item Technical Report 3GPP TS 22.220 Service requirements for Home Node B 3GPP TS 25.467 UTRAN architecture for 3G Home Node B (HNB); Stage 2 – UTRAN 3GPP TS 25.469 UTRAN Iuh interface Home Node B (HNB) Application Part (HNBAP) signaling 3GPP TR 21.905 "Vocabulary for 3GPP Specifications". 3GPP TS 25.468 "UTRAN Iuh Interface RUA signaling". 3GPP TS 25.
RADWIN 6000 Chapter 1 The RADWIN 6000ODU is shown in Figure 1-2 below: Figure 1-2: Left, front, center rear, right top, top ports, right bottom, bottom ports Related Equipment and Accessories Lightning Protector Lightning protection is mandatory for radio links. RADWIN supplies a lightning protector device designed for use with RADWIN products. Figure 1-14: Left: RADWIN Lightning Protector Right: Using RADWIN lightning protectors RADWIN 6000 Reference Guide Release 6.1.
Chapter 2 Hardware Installation This chapter sets out the requirements and procedures for the hardware installation of the RADWIN 6000. It is intended to guide qualified field technicians. Warning Outdoor units and antennas should be installed ONLY by experienced installation professionals who are familiar with local building and safety codes and, wherever applicable, are licensed by the appropriate government regulatory authorities.
Hardware Installation Chapter 2 The RADWIN 6000 ODU must be grounded to a Protective Earth as described in and in accordance with the Local Electrical Regulations.
Hardware Installation Chapter 2 Table 2-1: Bill of Materials: ODU mounting kit Item Qty Large Clamp (see Figure 2-1) 1 Small Clamp (see Figure 2-2) 1 Arm (see Figure 2-3) 1 Screw hex head M8x40 4 4 Screw hex head M8x70 2 2 Washer flat M8 4 4 Washer spring M8 3 3 M8 Nuts 2 2 Figure 2-1: Large Clamp Figure 2-2: Small Clamp Figure 2-3: Arm Figure 2-4: Accessories The RADWIN 6000 ODU is shown in Figure 2-5 below: Figure 2-5: Left, front, center rear, right top, top ports, right bottom, bot
Hardware Installation Chapter 2 Tools and Materials • • • • • Crimping tool for RJ-45 (if the ODU-PoE cable is without connectors) Spanner/wrench 13 mm (½”) Drill (for wall mounting only) Cable ties Sealing material Cables and connectors • CAT 5e LAN cable • PoE-out cable (outdoor class, CAT-5e, 4 twisted pairs, 24AWG), up to 100 m. for 100BaseT connection. For a 1000BaseT connection (HBS only) use an ODU-PoE cable no longer than 75m.
Hardware Installation Chapter 2 Mounting the Lightning Protection Devices The use of lightning protection is dependent on regulatory and end user requirements. The RADWIN 6000 ODU is designed with surge limiting circuits to minimize the risk of damage due to lightning strikes. RADWIN recommends the use of additional lightning protector devices to protect the equipment from nearby lightning strikes. Refer to Chapter 4 for detailed installation instructions for use of lightning protection devices.
Mounting the Lightning Protection Devices The use of lightning protection is dependent on regulatory and end user requirements. The RADWIN 6000 ODU is designed with surge limiting circuits to minimize the risk of damage due to lightning strikes. RADWIN recommends the use of additional lightning protector devices to protect the equipment from nearby lightning strikes. Figure 2-6: RADWIN Lightning Protector Right: Using RADWIN lightning protectors RADWIN 6000 Reference Guide Release 6.1.
Chapter 3 Lightning Protection and Grounding Guidelines Meticulous implementation of the guidelines in this chapter will provide best protection against electric shock and lightning. 100% protection is neither implied nor possible. Warning Note This chapter is at best a guide. The actual degree of lightning protection required depends on local conditions and regulations.
Using Lightning Protectors and Grounding Chapter 3 The RADWIN Lightning Protection System consists of the following components: • • Grounding for ODU • External Primary Lightning Protector units and grounding for the outdoor cable • Internal ESD protection circuits over the Power/Telecom lines ODU Grounding RADWIN Lightning Protection System uses a Shielded CAT 5e cable to interconnect the Outdoor (ODU) and Indoor (IDU) units.
Using Lightning Protectors and Grounding Chapter 3 The RADWIN Lightning Protection Kit The RADWIN lightning protection kit contains the items as shown in Figure 3-2: Figure 3-2: RADWIN Lightning Protection Kit The lightning protector incorporates high-power gas discharge tube and current transistor protection in a single protector unit. Technical specifications are shown in .
Using Lightning Protectors and Grounding Chapter 3 Figure 3-3: Grounding a typical pole installation RADWIN 6000 Reference Guide Release 6.1.
Using Lightning Protectors and Grounding Chapter 3 Figure 3-4: Grounding a typical wall installation The next figure shows a close-up of the rear of grounded ODU: Figure 3-5: ODU Lightning Protector and grounding RADWIN 6000 Reference Guide Release 6.1.
Using Lightning Protectors and Grounding Chapter 3 Mounting RADWIN Lighting Protection unit To mount a lightning protection device: Mount the device as close to the ODU as possible. Mount the unit to on the pole using the supplied band. Connect the ODU-IDU cable using the RJ-45 jack. Connect one cable between the ODU and the protector using an RJ-45 jack. Connect the protector’s ground stud to a grounding point.
Using Lightning Protectors and Grounding Chapter 3 Figure 3-6: Lightning protector and grounding at building entry point Internal ESD Protection circuits RADWIN equipment is designed to meet the ETSI/FCC/Aus/NZ/CSA EMC and Safety require-ments. To fulfill these requirements, the system's Telecom lines at the ODU/IDU are Trans-former-isolated and include internal ESD (Electro-Static-Discharge) Protection circuits. RADWIN 6000 Reference Guide Release 6.1.
Appendix A Technical Specifications Scope of these Specifications This appendix contains technical specifications for the RADWIN 6000 appearing in this User Manual. They are correct at the date of publication, but are intended for general background only. The latest authoritative and most up to date technical specifications are available as Data Sheets obtainable from RADWIN Customer Service. In any event, RADWIN reserves the right to change these specifications without notice.
Tech Spec Appendix A Environmental Operating Temperatures - 30°C to +50°C / - 22°F to +122°F Humidity Up to 100% non-condensing, IP67 Storage -40° to 85°C / -40°F to 185°F Safety FCC/IC (cTUVus) UL 60950-1, UL 60950-22, CAN/CSA C22.2 60950-1, CAN/CSA C22.
Tech Spec Appendix A Lightning Protector Electrical Compatible Interfaces 10/100/1000BaseT Data Rates Up to 1000Mbps Nominal Operational Voltage 48 VDC Maximum Operational Voltage 60 VDC - 650 mA Maximum Continues current 1A Impedance 90 to 110 Ohm Connection type RJ45 CAT 5e STP (shielded) Pin-out 8 wires + shielding Pins Protected All pins protected Response time <5 microseconds (with ODU) Nominal discharge currents Line to Line 500 A @ 8/20μs Line to Ground 2000 A @ 8/20 μs Impu
Antenna Characteristics Appendix A Enclosure rating IP67 Humidity 100% non condensing RADWIN 6000 Reference Guide Release 6.1.