Operating instructions

Product Options QAM256 Digital Video Modulator and Upconverter
B-6 TM077 – Rev. 4.0
radQAM256TxMinorAlarm2Status OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this to the value '00000000'B
Bits 0..7 Spares
0 = Pass, 1 = Fail"
::= { radQAM256ModStatus 4 }
radQAM256TxCommonAlarm1Status OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this to the value '00000000'B
Bit 0=Interface hardware fault 1=Fault
Bit 1=M&C Hardware Fault
Bit 2...7 Spares
0 = Pass, 1 = Fail"
::= { radQAM256ModStatus 5 }
radQAM256TxCommonAlarm2Status OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this to
the value '00000000'B
Bits 0 ..7 Spares
0 = Pass, 1 = Fail"
::= { radQAM256ModStatus 6 }
radQAM256TxLatchedMajorAlarm1Status OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this to the value '00000000'B
Bit 0=Mod Hardware fault
Bit 1=Tx Synthesizer fault
Bit 2=Tx Data PLL lock fault
Bit 3=Tx Framing Lock (Unused)
Bit 4=Mod Chip 1 Lock fault (Unused)
Bit 5=Mod Chip 2 Lock fault (Unused)
Bit 6=Mod Chip 3 Lock fault (Current chip used)
Bit 7=Spare
0 = Pass, 1 = Fail"
::= { radQAM256ModStatus 7 }
radQAM256TxLatchedMajorAlarm2Status OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
"Bits 0 ..7 Spares"
::= { radQAM256ModStatus 8 }
radQAM256TxLatchedMinorAlarm1Status OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this to the value '00000000'B
Bit 0=Clock activity detect fault
Bit 1=Data activity detect fault