Brochure
8
COMMON SYSTEM DATA
Front panel
Panel cut-out
The actuators featured in the RAFIX 22
FS
+
series are suitable for 22.3 mm pan-
elcut-outsaccordingtoIEC60947-5-1.All
actuators are equipped with a locating
pip. This locating pip ensures the perfect
fit of actuators and contact blocks for
PCB-mounted components and is there-
fore essential for a design built with
these contact blocks.
Grid spacing
The design principle makes it possible
to use a minimum grid spacing of
30 mm x 30 mm. In such an arrange-
ment, actuators with square collars can
be aligned directly without any gaps.
When designing the grid spacing, it is
recommendedtoconsideranyexternal
legendingrequired(for example, using
labels strips inserted into the front
panel).
Assembly of the front actuators
Single-handed assembly method
Forassembly, insert the actuatorinto the mounting hole fromthe front side.It is
clampedinthepanelcutout.Subsequentlyyoucanscrewontheactuatorfromthe
rear using the ring nut. You can perform these steps one after the other with one
hand!Evenbetter:youcanstartbyinsertingallactuatorsfromthefrontsiderstand
subsequently fasten the threaded rings from the rear in one go. We recommend us-
ingtheRAFIXxingspannertoensurepropertightening.
FAST & SLIM
RAFIX 22 FS
+