Specification

Spray Nozzles
www.rainbird.com/sprays
29
The Intelligent Use of Water.
0° Trajectory
  Q V
Nozzle Pressure Radius Flow Precip Precip
psi ft. gpm In/h In/h
330° Arc 15 4 0.85 5.58 6.44
20 5 0.96 4.03 4.65
25 5 1.09 4.58 5.29
30 6 1.20 3.50 4.04
270° Arc 15 4 0.79 6.34 7.32
20 5 0.88 4.52 5.22
25 5 1.00 5.13 5.92
30 6 1.10 3.92 4.53
180° Arc 15 4 0.42 5.05 5.83
20 5 0.49 3.77 4.35
25 5 0.55 4.24 4.90
30 6 0.60 3.21 3.71
90° Arc 15 4 0.26 6.26 7.23
20 5 0.30 4.62 5.33
25 5 0.34 5.24 6.05
30 6 0.37 3.96 4.57
6 Series VAN
0° Trajectory
 Q V
Nozzle Pressure Radius Flow Flow Precip Precip
bar m m3⁄h l/m mm/h mm/h
330° Arc 1.0 1.2 0.19 3.2 144 166
1.5 1.5 0.23 3.8 112 129
2.0 1.8 0.27 4.5 91 105
2.1 1.8 0.27 4.5 91 105
270° Arc 1.0 1.2 0.18 3.0 167 193
1.5 1.5 0.21 3.5 124 143
2.0 1.8 0.24 4.1 99 114
2.1 1.8 0.25 4.2 103 119
180° Arc 1.0 1.2 0.10 1.6 139 161
1.5 1.5 0.11 1.9 98 113
2.0 1.8 0.13 2.2 80 92
2.1 1.8 0.14 2.3 86 99
90° Arc 1.0 1.2 0.06 1.0 167 193
1.5 1.5 0.07 1.2 124 143
2.0 1.8 0.08 1.4 99 114
2.1 1.8 0.08 1.4 99 114
6 Series VAN METRIC
0° Trajectory
  Q V
Nozzle Pressure Radius Flow Precip Precip
psi ft. gpm In/h In/h
330° Arc 15 3 0.62 7.23 8.35
20 3 0.70 8.17 9.43
25 4 0.80 5.25 6.06
30 4 0.88 5.78 6.67
270° Arc 15 3 0.52 7.42 8.57
20 3 0.58 8.27 9.55
25 4 0.66 5.29 6.11
30 4 0.73 5.86 6.77
180° Arc 15 3 0.32 6.84 7.90
20 3 0.37 7.91 9.13
25 4 0.41 4.93 5.69
30 4 0.45 5.41 6.25
90° Arc 15 3 0.21 8.98 10.37
20 3 0.24 10.27 11.86
25 4 0.26 6.26 7.23
30 4 0.29 6.98 8.06
4 Series VAN
0° Trajectory
 Q V
Nozzle Pressure Radius Flow Flow Precip Precip
bar m m3⁄h l/m mm/h mm/h
330° Arc 1.0 0.9 0.14 2.3 189 218
1.5 1.0 0.17 2.8 183 215
2.0 1.2 0.20 3.3 152 176
2.1 1.2 0.20 3.3 152 176
270° Arc 1.0 0.9 0.12 2.0 198 229
1.5 1.0 0.14 2.3 187 216
2.0 1.2 0.16 2.7 148 171
2.1 1.2 0.17 2.8 157 181
180° Arc 1.0 0.9 0.07 1.2 173 200
1.5 1.0 0.09 1.5 180 208
2.0 1.2 0.10 1.7 139 161
2.1 1.2 0.10 1.7 139 161
90° Arc 1.0 0.9 0.05 0.8 247 285
1.5 1.0 0.06 0.9 240 277
2.0 1.2 0.06 1.1 167 193
2.1 1.2 0.07 1.1 194 224
4 Series VAN METRIC
Note: Turning the radius reduction screw may be required to achieve catalog radius
and flow when the arc is set at less than maximum arc
Q Square spacing based on 50% diameter of throw
V Triangular spacing based on 50% diameter of throw
Performance data taken in zero wind conditions
Spray Nozzles
VAN Series Nozzles

Summary of content (4 pages)