TABLE 9-5: MINIMUM FLOW REQUIREMENT FOR PROPER VALVE PERFORMANCE*
Valve Series
DV
(3/4", 1")
ASVF
(3/4", 1")
PGA (1") PEB (1") GB (1") EFB-CP (1")
Minimum Flow 3 GPM 3 GPM 2 GPM 0.25 GPM 5 GPM 5 GPM
* Assumes no filtration is provided upstream of the valve as described in Table 9-4.
Page 70 Chapter 9
Flow Compatibility
It is important to note that all electric control valves have a minimum flow
specification that can be found in the valve manufacturer’s catalog. For Rain
Bird, these minimum flow rates are listed in Table 9-5. If the flow in a drip
hydrozone falls below the valve’s minimum flow specification and this goes
unchecked, trouble can occur. Water weepage from the valve or a valve that just
won’t shut off electrically are two of the more common problems that occur,
especially in drip retrofit situations.
One way to avoid this low flow valve problem is to use one of Rain Bird’s
Xerigation Control Zones. These control zones put a 200-mesh filter immediately
upstream of the electric control valve and thereby deliver a minimum flow
specification of 0.2 GPM or 12 GPH. The drip filter is pressure-rated to 150 PSI so
it performs reliably upstream of the valve, under constant pressure. Rain Bird
also offers the 100-PEB valve, which has a very low minimum flow specification
of 0.25 GPM.
*
Lateral Pipe/Tubing
In low-volume systems, 1/2" distribution tubing is typically used for lateral
piping. You calculate the pressure loss in this tubing in the same way you do for
PVC pipe. Table 9-6 provides friction loss characteristics for XT-700, Rain Bird’s
thick-walled, heavy-duty 1/2" polyethylene tubing.
TABLE 9-4: MINIMUM/MAXIMUM FLOWS FOR PROPER VALVE PERFORMANCE
Flow GPM GPH
XACZ-075
PSI
XCZ-075
PSI
75-DVX
PSI
XCZ-100
PSI
100-PEB
PSI
1 60 5.1 3.5 2.5 1.0
3.0
3 180 5.1 3.5 2.5 1.0
2.6
5 300 5.4 3.6 2.9 1.2
2.0
10* 600 9.9 7.5 3.8 5.1
1.5
15* 900 15.9 12.7 4.2 8.8
2.0
20* 1200 24.2 20.2 5.1 14.3
2.5
XCZ-075 pressure loss data above 5 GPM is with PSI-M30X pressure regulator.
Maximum flow rate with "M" style regulators is 22 GPM.
* For flows below 3 GPM, always use RBY Series 200 mesh filter installed upstream of valve.
** For flows greater than 5 GPM, substitute PSI-L30X with a PSI-M30X pressure regulator.
*** Minimum flow rate of 100-PEB valve is 0.25 GPM without the use of an upstream filter
®