Safety Data Sheets (SDS)
_____________________________________________________________________________________________
11132 - Rain-X Glass Cleaner Wipes Revision Date 21-Jun-2018
Unsuitable extinguishing media
Do not use a solid water stream as it may scatter and spread fire.
Specific hazards arising from the chemical
Will not burn or support combustion. Keep product and empty container away from heat and sources of ignition. Risk of ignition.
Explosion data
Sensitivity to Mechanical Impact
None.
Sensitivity to Static Discharge
None.
Protective equipment and precautions for firefighters
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full
protective gear.
6. ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures
Personal precautions
Ensure adequate ventilation, especially in confined areas. Avoid contact with eyes and skin.
Use personal protective equipment as required. Remove all sources of ignition. Evacuate
personnel to safe areas. Keep people away from and upwind of spill/leak. Pay attention to
flashback. Take precautionary measures against static discharges.
Environmental precautions
Environmental precautions
See section 12 for additional ecological information. Do not flush into surface water or
sanitary sewer system. Prevent further leakage or spillage if safe to do so. Prevent product
from entering drains.
Methods and material for containment and cleaning up
Methods for containment
Prevent further leakage or spillage if safe to do so.
Methods for cleaning up
Ensure adequate ventilation. Collect spillage. Soak up with inert absorbent material. Dam
up. Pick up and transfer to properly labeled containers. Take precautionary measures
against static discharges.
Prevention of secondary hazards
Clean contaminated objects and areas thoroughly observing environmental regulations.
7. HANDLING AND STORAGE
Precautions for safe handling
Advice on safe handling
Handle in accordance with good industrial hygiene and safety practice. Use with local
exhaust ventilation. All equipment used when handling the product must be grounded. Keep
away from heat/sparks/open flames/hot surfaces. - No smoking. Use personal protective
equipment as required. Do not breathe dust/fume/gas/mist/vapors/spray. Take necessary
action to avoid static electricity discharge (which might cause ignition of organic vapors).
Conditions for safe storage, including any incompatibilities
Storage Conditions
Keep in a dry, cool and well-ventilated place. Keep out of the reach of children. Keep away
from heat, sparks, flame and other sources of ignition (i.e., pilot lights, electric motors and
static electricity). Keep containers tightly closed in a cool, well-ventilated place. Keep away
from heat. Keep in properly labeled containers.
Incompatible materials
None known based on information supplied
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
_____________________________________________________________________________________________
Page 3 / 8
Control parameters