Operation Manual

10
MANUAL OPERATIONS
SYSTEM TEST FACILITY
Turn the dial to Run Test Cycle.
There will be a two second pause.
THE DISPLAY WILL SHOW:
Use this feature to check that your
valves & sprinklers are working correctly. The unit will run all stations
in sequential order. The factory preset time of 2 minutes per station
can be adjusted. The new adjusted run time will become the new
default time.
TIP: If the water supply is from a pump system, it is critical to ensure all
outputs are connected to a valve. Any output NOT connected to a valve,
should be linked back with a wire to the nearest output with a valve.
This prevents the pump running against a closed head.
RUN A SINGLE STATION
Turn the dial to Run Single Station. There will be a two second pause.
To adjust the run time, use or . To advance to the next station
press the button. Maximum run
time is 12 hours 59 minutes.
THE DISPLAY WILL SHOW:
Unused
stations
linked
back to
last used
station