FIELD WIRING CONNECTIONS
PREPARATION
1 Prepare wires for hook-up by cutting the wires to the correct length
and stripping approximately 6mm inch) of insulation from the end
to be connected to the controller.
2 Ensure terminal block screws are loosened sufficiently to permit
easy access for wire ends. Insert stripped wire ends into the clamp
aperture and tighten screws. Do not over tighten as this may
damage the terminal block.
3 A maximum of 0.5 Amps may be supplied by any output. Check the
inrush current of your solenoid coils before connecting more than
two valves to any one station.
TERMINAL BLOCK LAYOUT
THE TERMINAL BLOCK IS LAID OUT AS FOLLOWS:
INSTALLATION INSTRUCTIONS
GLOSSARY
24VAC 24VAC Power Supply
C Common valve wire input
P Master valve or pump start active wire
1 to 6 Station (Valve) active wire connection